Part Number Hot Search : 
PKC136 PS1201 T8302 E13003 SP708R VPX3216B GP1006 HT46C64
Product Description
Full Text Search
 

To Download SRBA-06F2AX Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NON-ISOLATED DC/DC CONVERTERS
2.4 V-5.5 V Input 0.75 V-3.63 V/6 A Output
SRBA-06F2AX Series
* * * * * * * Non-Isolated High Efficiency High Power Density Excellent Thermal Performance Low Cost Remote On/Off Flexible Output Voltage Sequencing
RoHS Compliant
* * * * * * * Under-voltage Lockout (UVLO) OCP/SCP Wide Input Wide Trim Range Active Low/High (option) Able to Sink & Source Current Fixed Frequency (300 kHz)
Description
The Bel SRBA-06F2AX modules are a series of non-isolated dc-dc converters that deliver up to 6 A of output current with full load efficiency of 93% at 3.3 V output. These modules provide precisely regulated voltage programmable via external resistor from 0.75 V to 3.63 V over a wide range of input voltage (2.4 V-5.5 V). These modules have a sequencing feature that enables designers to implement various types of output voltage sequencing when powering multiple voltages on a board. The open-frame construction and small footprint enable designers to develop cost and space-efficient solutions. Standard features include remote On/Off, over current protection, short circuit protection, wide input, and programmable output voltage.
Part Selection
Output Voltage 0.75 V - 3.63 V
1
Input Voltage 2.4 V - 5.5 V
Max. Output Current 6A
Max. Output Power 21.8 W
Typical Efficiency 93%
Model Number Active Low SRBA-06F2AL
Model Number Active High SRBA-06F2A0
Notes: 1. These modules use a buck topology, so the output voltages must be 0.5 V less than the input voltage. 2. Add "G" to the end of the Model Number to indicate Tray Packaging.
Absolute Maximum Ratings
Parameter Input Voltage (continuous) Output Enable Terminal Voltage Sequencing Voltage
1
Min -0.3 V -0.3 V -0.3 V -40 C -55 C
Typ -
Max 5.8 V 5.5 V Vin 85 C 125 C
Notes
Ambient Temperature Storage Temperature
Notes: All specifications are typical at 25 C unless otherwise stated. 1. SRBA-06F2AX series of modules include a sequencing feature that enables users to implement various types of output voltage sequencing in their applications. This is accomplished via an additional sequencing pin. When the sequencing feature is not used, tie the SEQ pin to Vin.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com
NON-ISOLATED DC/DC CONVERTERS
2.4 V-5.5 V Input 0.75 V-3.63 V/6 A Output
Min 2.4 V Vo=3.3 V Vo=2.5 V Vo=1.8 V Vo=1.5 V Vo=1.2 V Vo=0.75 V Input Current (no load) Vo=3.3 V Vo=0.75 V Remote Off Input Current Input Reflected Ripple Current (pk-pk) Input Reflected Ripple Current (rms) I t Inrush Current Transient Turn-on Voltage Threshold Turn-off Voltage Threshold
2
Input Specifications
Parameter Input Voltage Input Current (full load) Typ 50 mA 25 mA 0.6 mA 120 mA 35 mA 2.05 V 2.0 V Max 5.5 V 4.73 A 5.49 A 5.11 A 4.31 A 3.57 A 2.40 A 0.04A s 2.4V 2
Notes Vo, set Vin-0.5 V
1.8 V
Tested with simulated source impedance of 1uH, 5 Hz to 20 MHz.
Output Specifications
Parameter Output Voltage Set Point Output Voltage Set Point Adjustment Range Selected by External Resistor or Voltage Load Regulation Line Regulation Regulation Over Temperature (-40 C to +85 C) Output Current Current Limit Threshold Short Circuit Surge Transient Ripple and Noise (pk-pk) Ripple and Noise (rms) Turn on Time Overshoot at Turn on Output Capacitance ESR 1mohm ESR 10mohm Transient Response 50% ~ 100% Max Load Settling Time 100% ~ 50% Max Load Settling Time VO = 0.75 V 3.63 V 130 mV 25 uS 130 mV 25 uS di/dt=2.5 A/ uS; Vin=5 V; and with 10 uF tantalum capacitor & 1 uF/10 V TDK ceramic capacitor at output Min -2%Vo,set -3%Vo,set 0.7525 V 0A 9A 0 uF 0 uF Typ 0.4%Vo,set 0.3%Vo,set 0.4%Vo,set 0.32 A s 40 mV 10 mV 6 mS 0% 2
Max 2%Vo,set 3%Vo,set 3.63 V 6A 18 A 70 mV 30 mV 10 mS 3% 1000 uF 3000 uF
Notes Vin=5 V, 50% full load Over all operating input voltages, resistive loads and temperature conditions Io=0%~50% full load; Io=50%~100% full load Vin=Vin, min to Vin, max Tref=Ta, min to Ta, max Hiccup mode Tested with 0-20 MHz, with 10 uF tantalum capacitor & 1uF/10 V ceramic capacitor at output
Note: All specifications are typical at nominal input, full load at 25 C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com
NON-ISOLATED DC/DC CONVERTERS
2.4 V-5.5 V Input
Parameter Efficiency Vo=3.3 V Vo=2.5 V Vo=1.8 V Vo=1.5 V Vo=1.2 V Vo=0.75 V Switching Frequency Over Temperature Shutdown Output Voltage Trim Range MTBF Dimensions Inches (L x W x H) Millimeters (L x W x H) Weight 0.8 x 0.45 x 0.25 20.32 x 11.42 x 6.36 5g 250 kHz 0.7525 V 93% 91% 88% 87% 84% 78% 300 kHz 135 C 6,954,974 hours 350 kHz 3.63 V Measured at Vin=5 V, full load
0.75 V-3.63 V/6 A Output
Min Typ Max Notes
General Specifications
Calculated Per Bell Core SR-332 (IO = Nominal; Ta = 25 C)
Note: All specifications are typical at 25 C unless otherwise stated.
Control Specifications
Parameter Remote On/Off Signal Low (Unit Off) Signal High (Unit On) Signal Low (Unit On) Signal High (Unit Off) Sequencing Voltage Sequencing Slew Rate Capability Sequencing Delay Time Tracking Accuracy Power-Up Power-Down 100 mV 200 mV 200 mV 400 mV Min -0.2 V -0.2 V 1.5 V 0V 10 mS Typ Max 0.3 V Vin, max 0.3 V Vin, max Vin 2 V/ mS Delay from Vin, min to application of voltage on SEQ pin Notes Active High: SRBA-06F2A0; Remote On/Off pin open, Unit on. Active Low: SRBA-06F2AL; Remote On/Off pin open, Unit on. Sequencing Voltage applied on SEQ pin should be higher than output voltage.
Output Trim Equations
Equation for calculating the trim resistor (in k) given the desired adjusted voltage (Vadj) is shown below. The Trim Up resistor should be connected between the Trim pin and Ground.
Vout
RTrimUp =
21.07 - 5.11 Vadj - 0.7525
Module Trim
GND
Rtrim
Equation for calculating the trim voltage (in V) given the desired adjusted voltage (Vadj) is shown below. The Trim Up voltage should be connected between the Trim pin and Ground.
Vout
VTrimUp = 0.7 - 0.1698 x (Vadj - 0.7525)
Module
Trim
Vtrim
GND
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com
NON-ISOLATED DC/DC CONVERTERS
2.4 V-5.5 V Input 0.75 V-3.63 V/6 A Output
Efficiency Data
3.3V Module 100.0% 95.0% 90.0%
2.5V Module 100.0% 95.0% 90.0% Efficiency
4.5V 5V 5.5V
Efficiency
85.0% 80.0% 75.0% 70.0% 65.0% 60.0% 0.6A 1.5A 3.0A Output Current 4.5A 6.0A
85.0% 80.0% 75.0% 70.0% 65.0% 60.0% 0.6A 1.5A 3.0A Output Current 4.5A 6.0A
3V 5V 5.5V
Vo=3.3 V
1.8V Module 100.0% 95.0% 90.0% Efficiency 85.0% 80.0% 75.0% 70.0% 65.0% 60.0% 0.6A 1.5A 3.0A Output Current 4.5A 6.0A
Vo=2.5 V
1.5V Module 100.0% 95.0% 90.0% Efficiency
3V 5V 5.5V
85.0% 80.0% 75.0% 70.0% 65.0% 60.0% 0.6A 1.5A 3.0A Output Current 4.5A 6.0A
3V 5V 5.5V
Vo=1.8 V
1.2V Module 100.0% 95.0% 90.0% Efficiency 85.0% 80.0% 75.0% 70.0% 65.0% 60.0% 0.6A 1.5A 3.0A Output Current 4.5A 6.0A
Vo=1.5 V
0.7525V Module 100.0% 95.0% 90.0% Efficiency
3V 5V 5.5V
85.0% 80.0% 75.0% 70.0% 65.0% 60.0% 0.6A 1.5A 3.0A Output Current 4.5A 6.0A
3V 5V 5.5V
Vo=1.2 V
Vo=0.7525 V
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com
NON-ISOLATED DC/DC CONVERTERS
2.4 V-5.5 V Input 0.75 V-3.63 V/6 A Output
Thermal Derating Curves
Vin=5.0 V, Vo=3.3 V
Vin=5.0 V, Vo=0.75 V
Vin=3.3 V, Vo=2.5 V
Vin=3.3 V, Vo=0.75 V
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 * Tel 201-432-0463 * Fax 201-432-9542 * www.belfuse.com
NON-ISOLATED DC/DC CONVERTERS
2.4 V-5.5 V Input 0.75 V-3.63 V/6 A Output
Mechanical Outline
Pin Connections
Pin 1 2 3 Function Remote On/Off Vin+ SEQ Ground Trim Vout+
PAD SIZE: MIN: 0.012"* 0.0095" (3.05mm * 2.41mm) MAX: 0.0135"* 0.011" (3.43mm * 2.79mm)
4 5 6
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products.
(c)2005 Bel Fuse Inc. Specifications subject to change without notice. 120905
CORPORATE Bel Fuse Inc. 206 Van Vorst Street Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com
FAR EAST Bel Fuse Ltd. 8F/ 8 Luk Hop Street San Po Kong Kowloon, Hong Kong Tel 852-2328-5515 Fax 852-2352-3706 www.belfuse.com
EUROPE Bel Fuse Europe Ltd. Preston Technology Management Centre Marsh Lane, Suite G7, Preston Lancashire, PR1 8UD, U.K. Tel 44-1772-556601 Fax 44-1772-888366 www.belfuse.com


▲Up To Search▲   

 
Price & Availability of SRBA-06F2AX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X